Coaxial Protection
675
© 2012 all rights reserved
DALLAS • KANSAS CITY • LOS ANGELES • MINNEAPOLIS • NEW YORK • PHOENIX • SACRAMENTO • SEATTLE
FAX 800-530-8821
www.talleycom.com
800-949-7079
Pricing subject to change without notice
For more detailed specs reference www.talleycom.com
dc Blocked, Single Channel Broadband HF/VHF/UHF Protectors
Broadband HF/VHF/UHF gas tube coaxial protector with multi-strike capability
for general radio use. Not recommended for transmitter combining. Not recom-
mended for transmitter combining.
Insertion Loss
VSWR
Surge
Impedance
Mounting
Warranty
<= 0.1 dB
1.1:1
50kA
50 Ohm
Bulkhead
10 Year
Turn-on Throughput
Order PN Frequency Range Power Connectors Voltage Energy List Level 1 Level 2 Level 3
IS-B50LN-C0
1.5-400 MHz HF 2kW, VHF 375W, UHF 125W N-Female 600 Vdc <=10mJ $69.00 55.20 51.75 49.68
IS-B50LU-C0
1.5-400 MHz HF 2kW, VHF 375W, UHF 125W UHF Female 600 Vdc <=10mJ $69.00 55.20 51.75 49.68
IS-B50HN-C0
1.5-400 MHz HF 3kW, VHF 500W, UHF 250W N-Female 1200 Vdc <=20mJ $75.00 60.00 56.25 54.00
IS-B50LN-C1
50-700 MHz VHF 375W, UHF 125W N-Female 600 Vdc <=600µJ $69.00 55.20 51.75 49.68
IS-B50LU-C1
50-700 MHz VHF 375W, UHF 125W UHF Female 600 Vdc <=600µJ $69.00 55.20 51.75 49.68
IS-B50HN-C1
50-700 MHz VHF 500W, UHF 250W N-Female 1200 Vdc <=1mJ $75.00 60.00 56.25 54.00
IS-B50LN-C2
125-1000 MHz VHF 375W, UHF 125W, 800-1000 N-Female 600 Vdc <=220µJ $69.00 55.20 51.75 49.68
MHz 50W
IS-B50HN-C2
125-1000 MHz VHF 500W, UHF 250W, 800-1000 N-Female 600 Vdc <=800µJ $75.00 60.00 56.25 54.00
MHz 125W
IS-B50HN-C1-MA
50-700 MHz VHF 500W, UHF 250W N-Female 1200 Vdc <=1mJ $75.00 60.00 56.25 54.00
IS-B50HN-C2-MA
125-1000 MHz VHF 500W, UHF 250W, 800-1000 N-Female 1200 Vdc <=800µJ $75.00 60.00 56.25 54.00
MHz 125W
IS-B50LN-C2-MA
125-1000 MHz VHF 375W, UHF 125W, 800-1000 N-Female 1200 Vdc <=220µJ $69.00 55.20 51.75 49.68
MHz 50W
IS-B50LN-C2-ME
125-1000 MHz VHF 375W, UHF 125W, 800-1000 N-Female 600 Vdc <=220µJ $69.00 55.20 51.75 49.68
MHz 50W
dc Blocked, Single Channel Broadband HF/VHF/UHF Protectors
Broadband HF/VHF/UHF gas tube coaxial protector with multi-strike capability
for general radio use. Not recommended for transmitter combining.
Connector options:-MA for male on antenna port. -ME for male on equipment
port.
Insertion Loss
VSWR
Surge
Impedance
Mounting
Warranty
<= 0.1 dB
1.1:1
50kA
50 Ohm
Flange
10 Year
Turn-on Throughput
Order PN Frequency Range Power Connectors Voltage Energy List Level 1 Level 2 Level 3
IS-50NX-C0
1.5-400 MHz HF 2kW, VHF 375W, UHF 125W N-Female 600 Vdc <=10mJ $62.00 49.60 46.50 44.64
IS-50UX-C0
1.5-400 MHz HF 2kW, VHF 375W, UHF 125W UHF Female 600 Vdc <=10mJ $66.00 52.80 49.50 47.52
IS-50NX-C1
50-700 MHz VHF 375W, UHF 125W N-Female 600 Vdc <=600µJ $62.00 49.60 46.50 44.64
IS-50UX-C1
50-700 MHz VHF 375W, UHF 125W UHF Female 600 Vdc <=600µJ $66.00 52.80 49.50 47.52
IS-50NX-C2
125-1000 MHz VHF 375W, UHF 125W, 800-1000 N-Female 600 Vdc <=220µJ $62.00 49.60 46.50 44.64
MHz 50W
IS-50NX-C1-MA
50-700 MHz VHF 375W, UHF 125W N-Female 600 Vdc <=600µJ $62.00 49.60 46.50 44.64
IS-50NX-C2-MA
125-1000 MHz VHF 375W, UHF 125W N-Female 600 Vdc <=220µJ $62.00 49.60 46.50 44.64
IS-50NX-C2-ME
125-1000 MHz VHF 375W, UHF 125W, 800-1000 N-Female 600 Vdc <=220µJ $62.00 49.60 46.50 44.64
MHz 50W
IS-50NX-C0-MA
1.5-400 MHz Hf: 2kW, VHF 375W, UHF 125W N-Female 600 Vdc <=10mJ $62.00 49.60 46.50 44.64
Coaxial
Protection
TalleyTestCatalog_1254301.QXD 4/12/2012 9:44 PM Page 675